DEENESPTFRRUARHIKOZHNL
CLASSIC Modul: com Rolle: constitutive Konfidenz: 95%

SNIP_CLASSIC_COM_SECTION_10_2_58_BswMDeadlineMonitoringControl

Quelle: SWS_BSWModeManager.pdf (Seite 148) • Ziel-Anforderung: SWS_Com_91004

Wortlaut

10.2.58 BswMDeadlineMonitoringControl [ECUC_BswM_00830] Definition of EcucParamConfContainerDef BswMDeadline MonitoringControl ⌈ Container Name BswMDeadlineMonitoringControl Parent Container BswMAvailableActions Description This container includes all parameters related to enabling and disabling of deadline monitoring for one or several PDUs in COM. Multiplicity 0..1 Configuration Parameters Included Parameters Parameter Name Multiplicity ECUC ID BswMDisabledDMPduGroupRef 0..* [ECUC_BswM_00852] BswMEnabledDMPduGroupRef 0..* [ECUC_BswM_00851] No Included Containers ⌋ [ECUC_BswM_00852] Definition of EcucReferenceDef BswMDisabledDMPdu GroupRef ⌈ Parameter Name BswMDisabledDMPduGroupRef Parent Container BswMDeadlineMonitoringControl Description This is a reference to a PDU Group for which the Deadline Monitoring should be disabled. This reference corresponds to the parameter "IpduGroupId" of the function Com_DisableReceptionDM. Multiplicity 0..* Type Symbolic name reference to ComIPduGroup Post-Build Variant Multiplicity true ▽ △ Post-Build Variant Value true Pre-compile time X VARIANT-PRE-COMPILE Link time X VARIANT-LINK-TIME Multiplicity Configuration Class Post-build time X VARIANT-POST-BUILD Pre-compile time X VARIANT-PRE-COMPILE Link time X VARIANT-LINK-TIME Value Configuration Class Post-build time X VARIANT-POST-BUILD Dependency ⌋ [ECUC_BswM_00851] Definition of EcucReferenceDef BswMEnabledDMPdu GroupRef ⌈ Parameter Name BswMEnabledDMPduGroupRef Parent Container BswMDeadlineMonitoringControl Description This is a reference to a PDU Group for which the Deadline Monitoring should be enabled. This reference corresponds to the parameter "IpduGroupId" of the function Com_EnableReceptionDM. Multiplicity 0..* Type Symbolic name reference to ComIPduGroup Post-Build Variant Multiplicity true Post-Build Variant Value true Pre-compile time X VARIANT-PRE-COMPILE Link time X VARIANT-LINK-TIME Multiplicity Configuration Class Post-build time X VARIANT-POST-BUILD Pre-compile time X VARIANT-PRE-COMPILE Link time X VARIANT-LINK-TIME Value Configuration Class Post-build time X VARIANT-POST-BUILD Dependency ⌋ [SWS_BswM_CONSTR_00003] ⌈The BswM shall reject configurations where a BswMDeadlineMonitoringControl container has a BswMDisabledDMPduGroupRef and a BswMEnabledDMPduGroupRef which reference the same PDU Group.⌋ [SWS_BswM_00274] Upstream requirements: SRS_ModeMgm_02007, SRS_ModeMgm_02003 ⌈When a BswMDeadlineMonitoringControl action is executed, the BswM shall call Com_EnableReceptionDM for each BswMEnabledDMPduGroupRef, and call Com_DisableReceptionDM for each BswMDisabledDMPduGroupRef. The ordering of these calls to Com is undefined.⌋ Note: If a strict ordering of the calls to Com_EnableReceptionDM, or Com_DisableReceptionDM is required, then this can be achieved by configuring individual actions (BswMDeadlineMonitoringControl, each with just a single BswM*PduGroupRef) within an ordered action list.

Versionen & Provenienz · Zugeordnete Anforderungen

Diese Angaben zeigt der Versions-Explorer.

Begründung & Zuweisungs-Evidenz

Cited verbatim in the snippet (deterministic citation).

Dokumenten-Herkunft & Rückverfolgbarkeit

Spezifikations-Dokument SWS_BSWModeManager.pdf
Dokumentseite Seite 148
Ziel-Modul com (classic)
Ziel-Anforderung SWS_Com_91004
Semantische Rolle constitutive
Automatisierungs-Konfidenz 0.95