DEENESPTFRRUARHIKOZHNL
CLASSIC Modul: com Rolle: constitutive Konfidenz: 95%

SNIP_CLASSIC_COM_SECTION_10_2_72_BswMPduGroupSwitch

Quelle: SWS_BSWModeManager.pdf (Seite 165) • Ziel-Anforderung: SWS_Com_91002

Wortlaut

10.2.72 BswMPduGroupSwitch [ECUC_BswM_00828] Definition of EcucParamConfContainerDef BswMPdu GroupSwitch ⌈ Container Name BswMPduGroupSwitch Parent Container BswMAvailableActions Description This container includes references to the PDU groups that shall be enabled and disabled. Multiplicity 0..1 Configuration Parameters Included Parameters Parameter Name Multiplicity ECUC ID BswMPduGroupSwitchReinit 0..1 [ECUC_BswM_00913] BswMDisabledPduGroupRef 0..* [ECUC_BswM_00850] BswMEnabledPduGroupRef 0..* [ECUC_BswM_00849] No Included Containers ⌋ [ECUC_BswM_00913] Definition of EcucBooleanParamDef BswMPduGroup SwitchReinit ⌈ Parameter Name BswMPduGroupSwitchReinit Parent Container BswMPduGroupSwitch Description This parameter defines if the data of the I-PDU, the shadow buffers of included signal groups, etc. are reinitialized when a PDU Group is started. This parameter corresponds to the parameter "initialize" of the function Com_IpduGroupStart. Multiplicity 0..1 Type EcucBooleanParamDef Default value false Post-Build Variant Multiplicity true Post-Build Variant Value true Pre-compile time X VARIANT-PRE-COMPILE Link time X VARIANT-LINK-TIME Multiplicity Configuration Class Post-build time X VARIANT-POST-BUILD Pre-compile time X VARIANT-PRE-COMPILE Link time X VARIANT-LINK-TIME Value Configuration Class Post-build time X VARIANT-POST-BUILD Dependency ⌋ [ECUC_BswM_00850] Definition of EcucReferenceDef BswMDisabledPduGroup Ref ⌈ Parameter Name BswMDisabledPduGroupRef Parent Container BswMPduGroupSwitch Description This is a reference to a PDU Group that should be disabled. This reference corresponds to the parameter "IpduGroupId" of the function Com_IpduGroupStop. Multiplicity 0..* Type Symbolic name reference to ComIPduGroup Post-Build Variant Multiplicity true Post-Build Variant Value true Pre-compile time X VARIANT-PRE-COMPILE Link time X VARIANT-LINK-TIME Multiplicity Configuration Class Post-build time X VARIANT-POST-BUILD Pre-compile time X VARIANT-PRE-COMPILE Link time X VARIANT-LINK-TIME Value Configuration Class Post-build time X VARIANT-POST-BUILD Dependency ⌋ [ECUC_BswM_00849] Definition of EcucReferenceDef BswMEnabledPduGroup Ref ⌈ Parameter Name BswMEnabledPduGroupRef Parent Container BswMPduGroupSwitch Description This is a reference to a PDU Group that should be enabled. This reference corresponds to the parameter "IpduGroupId" of the function Com_IpduGroupStart. ▽ △ Multiplicity 0..* Type Symbolic name reference to ComIPduGroup Post-Build Variant Multiplicity true Post-Build Variant Value true Pre-compile time X VARIANT-PRE-COMPILE Link time X VARIANT-LINK-TIME Multiplicity Configuration Class Post-build time X VARIANT-POST-BUILD Pre-compile time X VARIANT-PRE-COMPILE Link time X VARIANT-LINK-TIME Value Configuration Class Post-build time X VARIANT-POST-BUILD Dependency ⌋ [SWS_BswM_CONSTR_00004] ⌈The BswM shall reject configurations where a BswMPduGroupSwitch container has a BswMDisabledPduGroupRef and a BswMEnabledPduGroupRef which reference the same PDU Group.⌋ [SWS_BswM_00273] Upstream requirements: SRS_ModeMgm_02007, SRS_ModeMgm_02003 ⌈When a BswMPduGroupSwitch action is executed, the BswM shall call Com_IpduGroupStart for each BswMEnabledPduGroupRef, and call Com_IpduGroupStop for each BswMDisabledPduGroupRef. The ordering of these calls to Com is undefined.⌋ Note: If a strict ordering of the calls to Com_IpduGroupStart, or Com_IpduGroupStop is required, then this can be achieved by configuring individual actions (BswMPduGroupSwitch, each with just a single BswM*PduGroupRef) within an ordered action list.

Versionen & Provenienz · Zugeordnete Anforderungen

Diese Angaben zeigt der Versions-Explorer.

Begründung & Zuweisungs-Evidenz

Cited verbatim in the snippet (deterministic citation).

Dokumenten-Herkunft & Rückverfolgbarkeit

Spezifikations-Dokument SWS_BSWModeManager.pdf
Dokumentseite Seite 165
Ziel-Modul com (classic)
Ziel-Anforderung SWS_Com_91002
Semantische Rolle constitutive
Automatisierungs-Konfidenz 0.95