DEENESPTFRRUARHIKOZHNL
CLASSIC Modul: dem Rolle: constitutive Konfidenz: 95%

SNIP_CLASSIC_DEM_SECTION_8_3_3_21_Dem_RestartOperationCycle

Quelle: SWS_DiagnosticEventManager.pdf (Seite 274) • Ziel-Anforderung: SWS_Std_00005

Wortlaut

8.3.3.21 Dem_RestartOperationCycle [SWS_Dem_00194] Definition of API function Dem_RestartOperationCycle ⌈ Service Name Dem_RestartOperationCycle Syntax Std_ReturnType Dem_RestartOperationCycle ( uint8 OperationCycleId ) Service ID [hex] 0x08 Sync/Async Asynchronous Reentrancy Reentrant Parameters (in) OperationCycleId Identification of operation cycle, like power cycle, driving cycle. Parameters (inout) None Parameters (out) None Return value Std_ReturnType E_OK: set of operation cycle was accepted and will be handled asynchronously E_NOT_OK: set of operation cycle was rejected Description Sets an operation cycle state. This API can only be used through the RTE and therefore no declaration is exported via Dem.h. The interface has an asynchronous behavior to avoid exceeding of typical timing requirements on APIs if a large number of events has to be processed and during the re-initializations of the related monitors. The asynchronous acknowledgements are the related InitMonitorForEvent callbacks. Available via Dem.h ⌋

Versionen & Provenienz · Zugeordnete Anforderungen

Diese Angaben zeigt der Versions-Explorer.

Begründung & Zuweisungs-Evidenz

Cited verbatim in the snippet (deterministic citation).

Dokumenten-Herkunft & Rückverfolgbarkeit

Spezifikations-Dokument SWS_DiagnosticEventManager.pdf
Dokumentseite Seite 274
Ziel-Modul dem (classic)
Ziel-Anforderung SWS_Std_00005
Semantische Rolle constitutive
Automatisierungs-Konfidenz 0.95