DEENESPTFRRUARHIKOZHNL
CLASSIC Modul: fee Rolle: heuristic Konfidenz: 85%

SNIP_CLASSIC_FEE_FIGURE_Figure_6_11

Quelle: ErrorDescription.pdf (Seite 64) • Ziel-Anforderung: SWS_NvM_00864

Wortlaut

Figure 6.11: Information path for the Fee consistency check The Flash EEPROM Emulation checks the consistency of the read data (1). If a consistency error is detected, error status is forwarded to the NVRAM manager (2). The NVRAM manager reports NVM_E_INTEGRITY_FAILED to the DEM (3). Recovery is also initiated: "read retry", "read redundant block" and "read ROM block", if configured (4).If recovery actions imply a loss of redundancy or the use of ROM data, the NVRAM manager reports the loss of data quality via the job result. A DEM error is reported for the loss of redundancy (see Loss of redundancy). If the recovery fails (5), the job result is set to NVM_REQ_INTEGRITY_FAILED (6).

Versionen & Provenienz · Zugeordnete Anforderungen

Diese Angaben zeigt der Versions-Explorer.

Begründung & Zuweisungs-Evidenz

NvM reports NVM_E_INTEGRITY_FAILED on data corruption.

Dokumenten-Herkunft & Rückverfolgbarkeit

Spezifikations-Dokument ErrorDescription.pdf
Dokumentseite Seite 64
Ziel-Modul fee (classic)
Ziel-Anforderung SWS_NvM_00864
Semantische Rolle heuristic
Automatisierungs-Konfidenz 0.85