Wortlaut
Figure 6.11: Information path for the Fee consistency check The Flash EEPROM Emulation checks the consistency of the read data (1). If a consistency error is detected, error status is forwarded to the NVRAM manager (2). The NVRAM manager reports NVM_E_INTEGRITY_FAILED to the DEM (3). Recovery is also initiated: "read retry", "read redundant block" and "read ROM block", if configured (4).If recovery actions imply a loss of redundancy or the use of ROM data, the NVRAM manager reports the loss of data quality via the job result. A DEM error is reported for the loss of redundancy (see Loss of redundancy). If the recovery fails (5), the job result is set to NVM_REQ_INTEGRITY_FAILED (6).
Versionen & Provenienz · Zugeordnete Anforderungen
Diese Angaben zeigt der Versions-Explorer.
Begründung & Zuweisungs-Evidenz
NvM reports NVM_E_INTEGRITY_FAILED on data corruption.
Dokumenten-Herkunft & Rückverfolgbarkeit
| Spezifikations-Dokument | ErrorDescription.pdf |
|---|---|
| Dokumentseite | Seite 64 |
| Ziel-Modul | fee (classic) |
| Ziel-Anforderung | SWS_NvM_00864 |
| Semantische Rolle | heuristic |