DEENESPTFRRUARHIKOZHNL
CLASSIC Modul: frif Rolle: heuristic Konfidenz: 80%

SNIP_CLASSIC_FRIF_SECTION_7_6_5_2_ProvideTxConfirmation

Quelle: SWS_FlexRayInterface.pdf (Seite 37) • Ziel-Anforderung: SWS_Mirror_01026

Wortlaut

7.6.5.2 ProvideTxConfirmation This Communication Operation provides a Tx confirmation and optionally checks the occurrence of a Tx conflict. [SWS_FrIf_05064] ⌈If the related CC is in FrIf_State FRIF_STATE_ONLINE for a Communication Operation TX_CONFIRMATION, then the Job List Execution Function shall execute this Communication Operation. Otherwise, the Job List Execution Function shall ignore this Communication Operation.⌋() [SWS_FrIf_05288] ⌈"For a Communication Operation TX_CONFIRMATION the Job List Execution Function shall perform the following steps: 1. Call the FlexRay Driver’s API function Fr_CheckTxLPduStatus(): • Fr_CtrlIdx is derived according to the indexing scheme described in chapter of indexing • Fr_LPduIdx is set to the configured L-PDU buffer index [Configuration Parameter FrIfLPduIdx, see FrIf06058] associated with the Communication Operation. • Fr_SlotAssignmentPtr is set to a temporary slot assignment buffer if Bus Mirroring is enabled globally (see FrIfBusMirroringSupport), otherwise to the NULL_PTR. 2. If the transmission was performed (output parameter *Fr_TxLPduStatusPtr is set to FR_TRANSMITTED) then iterate over all PDUs contained in the FrIfFrame Structure (see FrIf05370) of the associated frame triggering. If TxConfCounter for a PDU is 0 proceed with the next PDU, otherwise • If FrIfConfirm == true, call the upper layer’s function <UL_TxConfirmation(E_ OK)> with the asociated PDUId (defined by the upper layer). • If FrIfConfirm == true , decrement TxConfCounter. 3. If the transmission was performed but a TxConflict occurred (output parameter *Fr_TxLPduStatusPtr is set to FR_TRANSMITTED_CONFLICT) then iterate over all PDUs contained in the FrIfFrameStructure (see FrIf05370) of the associated frame triggering. If TxConfCounter for a PDU is 0 proceed with the next PDU, otherwise • If FrIfConfirm == true, call the upper layer’s function <UL_TxConfirmation(E_ NOT_OK)> with the asociated PDUId (defined by the upper layer). • If FrIfConfirm == true , decrement TxConfCounter. 4. If Bus Mirroring is enabled globally (see FrIfBusMirroringSupport) and has been activated with a call to FrIf_EnableBusMirroring() for the Fr_CtrlIdx and the API Fr_CheckTxLpduStatus() returns "FR_TRANSMITTED_CONFLICT", call Mirror_ ReportFlexRayFrame() with "controllerId" set to Fr_CtrlIdx, "slotId", "cycle", and "channel" taken from Fr_SlotAssignmentPtr, "frame" set to the NULL_PTR, and "txConflict" set to true. If the API Fr_CheckTxLpduStatus() returns "FR_TRANSMITTED_CONFLICT" and the <UL_TxConflictNotification> is configured via FrIfTxConflictNotificationName (ECUC_ FrIf_06122), call this function for the same LPduIdx.⌋()

Versionen & Provenienz · Zugeordnete Anforderungen

Diese Angaben zeigt der Versions-Explorer.

Begründung & Zuweisungs-Evidenz

Reports mirrored frame with Tx conflict

Dokumenten-Herkunft & Rückverfolgbarkeit

Spezifikations-Dokument SWS_FlexRayInterface.pdf
Dokumentseite Seite 37
Ziel-Modul frif (classic)
Ziel-Anforderung SWS_Mirror_01026
Semantische Rolle heuristic
Automatisierungs-Konfidenz 0.80