DEENESPTFRRUARHIKOZHNL
CLASSIC Modul: linif Rolle: constitutive Konfidenz: 95%

SNIP_CLASSIC_LINIF_SECTION_9_2_3_LinIf_module_I_PDU_transmission

Quelle: SWS_PDURouter.pdf (Seite 107) • Ziel-Anforderung: SWS_Std_00005

Wortlaut

9.2.3 LinIf module I-PDU transmission Following Figure 9.7 shows transmission of I-PDU from the COM module to the LinIf module using transmit and later trigger transmit functions. In this case the I-PDU is a LIN sporadic frame. «module» LinIf «module» PduR «module» Com                                                                                                       PduR_<User:Lo>TriggerTransmit(Std_ReturnType, PduIdType, PduInfoType*) Com_TxConfirmation(PduIdType, Std_ReturnType) set flag() LinIf_Transmit(Std_ReturnType, PduIdType, const PduInfoType*) Com_TriggerTransmit(Std_ReturnType, PduIdType, PduInfoType*) PduR_ComTransmit(Std_ReturnType, PduIdType, const PduInfoType*) copy buffer() PduR_<User:Lo>TxConfirmation(PduIdType, Std_ReturnType) Figure 9.7: Com to LinIf I-PDU transmission (LIN sporadic frame) Following Figure 9.8 shows transmission of I-PDU from the COM module to the LinIf module using trigger transmit. In this case the I-PDU is all other types except LIN sporadic frame. «module» LinIf «module» PduR «module» Com                                                                                                                                                         PduR_<User:Lo>TriggerTransmit(PduIdType, PduInfoType*) Com_TxConfirmation(PduIdType, Std_ReturnType) PduR_<User:Lo>TxConfirmation(PduIdType, Std_ReturnType) copy buffer() Com_TriggerTransmit(Std_ReturnType, PduIdType, PduInfoType*) Figure 9.8: Com to LinIf I-PDU transmission (LIN sporadic non-frame)

Versionen & Provenienz · Zugeordnete Anforderungen

Diese Angaben zeigt der Versions-Explorer.

Begründung & Zuweisungs-Evidenz

Cited verbatim in the snippet (deterministic citation).

Dokumenten-Herkunft & Rückverfolgbarkeit

Spezifikations-Dokument SWS_PDURouter.pdf
Dokumentseite Seite 107
Ziel-Modul linif (classic)
Ziel-Anforderung SWS_Std_00005
Semantische Rolle constitutive
Automatisierungs-Konfidenz 0.95