DEENESPTFRRUARHIKOZHNL
CLASSIC Modul: pwm Rolle: constitutive Konfidenz: 95%

SNIP_CLASSIC_PWM_SECTION_7_6_2_Runtime_Errors

Quelle: SWS_PWMDriver.pdf (Seite 20) • Ziel-Anforderung: SWS_Pwm_00202

Wortlaut

7.6.2 Runtime Errors [SWS_Pwm_00202] Definition of runtime errors in module Pwm ⌈ Type of error Related error code Error value API Pwm_SetPowerState is called while the PWM module is still in use. PWM_E_NOT_DISENGAGED 0x16 ⌋ [SWS_Pwm_00200] ⌈The API shall report the runtime error PWM_E_NOT_DISENGAGED in case this API is called when one or more HW channels (where applicable) are in a state different than IDLE (or similar non-operational states) and/or there are still notification registered for the HW module channels.⌋

Versionen & Provenienz · Zugeordnete Anforderungen

Diese Angaben zeigt der Versions-Explorer.

Begründung & Zuweisungs-Evidenz

Cited verbatim in the snippet (deterministic citation).

Dokumenten-Herkunft & Rückverfolgbarkeit

Spezifikations-Dokument SWS_PWMDriver.pdf
Dokumentseite Seite 20
Ziel-Modul pwm (classic)
Ziel-Anforderung SWS_Pwm_00202
Semantische Rolle constitutive
Automatisierungs-Konfidenz 0.95