DEENESPTFRRUARHIKOZHNL
CLASSIC Modul: pwm Rolle: constitutive Konfidenz: 98%

SNIP_CLASSIC_PWM_SECTION_8_3_8_Pwm_EnableNotification

Quelle: SWS_PWMDriver.pdf (Seite 35) • Ziel-Anforderung: SWS_Pwm_91004

Wortlaut

8.3.8 Pwm_EnableNotification [SWS_Pwm_91004] Definition of API function Pwm_EnableNotification ⌈ Service Name Pwm_EnableNotification Syntax void Pwm_EnableNotification ( Pwm_ChannelType ChannelNumber, Pwm_EdgeNotificationType Notification ) Service ID [hex] 0x07 Sync/Async Asynchronous Reentrancy Reentrant for different channel numbers ChannelNumber Numeric identifier of the PWM Parameters (in) Notification Type of notification PWM_RISING_EDGE or PWM_FALLING_ EDGE or PWM_BOTH_EDGES Parameters (inout) None Parameters (out) None Return value None Description Service to enable the PWM signal edge notification according to notification parameter. Available via Pwm.h ⌋ [SWS_Pwm_00024] Upstream requirements: SRS_Pwm_12378, SRS_Pwm_12299 ⌈The function Pwm_EnableNotification shall enable the PWM signal edge notification according to notification parameter.⌋ [SWS_Pwm_00081] ⌈The function Pwm_EnableNotification shall cancel pending interrupts.⌋ [SWS_Pwm_10113] ⌈The function Pwm_EnableNotification shall be pre compile time configurable On/Off using the configuration parameter: PwmNotificationSupported.⌋ [SWS_Pwm_20113] ⌈The function Pwm_EnableNotification shall be configurable On/Off by the configuration parameter: PwmNotificationSupported {PWM_NOTIFICATION_SUPPORTED}. Regarding error detection, the requirements [SWS_Pwm_00117], [SWS_Pwm_00047], [SWS_Pwm_10051] and [SWS_Pwm_20051] are applicable to the function Pwm_EnableNotification.⌋

Versionen & Provenienz · Zugeordnete Anforderungen

Diese Angaben zeigt der Versions-Explorer.

Begründung & Zuweisungs-Evidenz

Explicit mention of SWS_Pwm_91004 in the text of document AUTOSAR_CP_SWS_PWMDriver.pdf.

Dokumenten-Herkunft & Rückverfolgbarkeit

Spezifikations-Dokument SWS_PWMDriver.pdf
Dokumentseite Seite 35
Ziel-Modul pwm (classic)
Ziel-Anforderung SWS_Pwm_91004
Semantische Rolle constitutive
Automatisierungs-Konfidenz 0.98