DEENESPTFRRUARHIKOZHNL
CLASSIC Modul: secoc Rolle: constitutive Konfidenz: 98%

SNIP_CLASSIC_SECOC_SECTION_8_3_2_SecOC_DeInit

Quelle: SWS_SecureOnboardCommunication.pdf (Seite 65) • Ziel-Anforderung: SWS_SecOC_00161

Wortlaut

8.3.2 SecOC_DeInit [SWS_SecOC_00161]⌈ Service Name SecOC_DeInit Syntax void SecOC_DeInit ( void ) Service ID [hex] 0x05 Sync/Async Synchronous Reentrancy Non Reentrant Parameters (in) None Parameters (inout) None Parameters (out) None Return value None Description This service stops the secure onboard communication. All buffered I-PDU are removed and have to be obtained again, if needed, after SecOC_Init has been called. By a call to SecOC_DeInit the AUTOSAR SecOC module is put into a not initialized state (SecOC_UNINIT). Available via SecOC.h ⌋(SRS_BSW_00323, SRS_BSW_00359, SRS_SecOC_00006, SRS_SecOC_00020) [SWS_SecOC_00157]⌈ Within SecOC_DeInit the module shall clear all internal global variables and the buffers of the SecOC I-PDUs. ⌋(SRS_BSW_00323, SRS_SecOC_00006)

Versionen & Provenienz · Zugeordnete Anforderungen

Diese Angaben zeigt der Versions-Explorer.

Begründung & Zuweisungs-Evidenz

Explicit mention of SWS_SecOC_00161 in the text of document AUTOSAR_CP_SWS_SecureOnboardCommunication.pdf.

Dokumenten-Herkunft & Rückverfolgbarkeit

Spezifikations-Dokument SWS_SecureOnboardCommunication.pdf
Dokumentseite Seite 65
Ziel-Modul secoc (classic)
Ziel-Anforderung SWS_SecOC_00161
Semantische Rolle constitutive
Automatisierungs-Konfidenz 0.98