ADC Driver (Adc)
Provides initialization and conversion services for analog-to-digital converters.
Funktionen — Übersicht
void Adc_Init (const Adc_ConfigType* ConfigPtr);Initializes the ADC hardware units and driver.Std_ReturnType Adc_SetupResultBuffer (Adc_GroupType Group, Adc_ValueGroupType* DataBufferPtr);Initializes ADC driver with the group specific result buffer start address where the conversion results will be stored.void Adc_DeInit (void);Returns all ADC HW Units to a state comparable to their power on reset state.void Adc_StartGroupConversion (Adc_GroupType Group);Starts the conversion of all channels of the requested ADC Channel group.void Adc_StopGroupConversion (Adc_GroupType Group);Stops the conversion of the requested ADC Channel group.Std_ReturnType Adc_ReadGroup (Adc_GroupType Group, Adc_ValueGroupType* DataBufferPtr);Reads the group conversion result of the last completed conversion round of the requested group and stores the channe l values...void Adc_EnableHardwareTrigger (Adc_GroupType Group);Enables the hardware trigger for the requested ADC Channel group.void Adc_DisableHardwareTrigger (Adc_GroupType Group);Disables the hardware trigger for the requested ADC Channel group.void Adc_EnableGroupNotification (Adc_GroupType Group);Enables the notification mechanism for the requested ADC Channel group.void Adc_DisableGroupNotification (Adc_GroupType Group);Disables the notification mechanism for the requested ADC Channel group.Adc_StatusType Adc_GetGroupStatus (Adc_GroupType Group);Returns the conversion status of the requested ADC Channel group.Adc_StreamNumSampleType Adc_GetStreamLastPointer (Adc_GroupType Group, Adc_ValueGroupType* * PtrToSamplePtr);Returns the number of valid samples per channel, stored in the result buffer.void Adc_GetVersionInfo (Std_VersionInfoType* versioninfo);Returns the version information of this module.Std_ReturnType Adc_SetPowerState (Adc_PowerStateRequestResultType* Result);This API configures the Adc module so that it enters the already prepared power state, chosen between a predefined set of...Std_ReturnType Adc_GetCurrentPowerState (Adc_PowerStateType* CurrentPowerState, Adc_PowerStateRequestResultType* Result);Service Adc_GetCurrentPowerState.Std_ReturnType Adc_GetTargetPowerState (Adc_PowerStateType* TargetPowerState, Adc_PowerStateRequestResultType* Result);Service Adc_GetTargetPowerState.Std_ReturnType Adc_PreparePowerState (Adc_PowerStateType PowerState, Adc_PowerStateRequestResultType* Result);This API starts the needed process to allow the ADC HW module to enter thevoid Adc_Main_PowerTransitionManager (void);This API is cyclically called and supervises the power state transitions, checking for the readiness of the module and issuing...void IoHwAb_Adc_NotifyReadyForPower (void);The API shall be invoked by the ADC Driver when the requested power state preparation for mode is completed.
Typen — Übersicht
struct Adc_ConfigTypeData structure containing the set of configuration parameters required for initializing the ADC Driver and ADC HW Unit(s).Adc_ChannelTypeNumeric ID of an ADC channel.Adc_GroupTypeNumeric ID of an ADC channel group.Adc_ValueGroupTypeType for reading the converted values of a channel group (raw, without further scaling, alignment according precompile switch...Adc_PrescaleTypeType of clock prescaler factor.Adc_ConversionTimeTypeType of conversion time, i.Adc_SamplingTimeTypeType of sampling time, i.Adc_ResolutionTypeType of channel resolution in number of bits.enum Adc_StatusTypeCurrent status of the conversion of the requested ADC Channel group.Adc_TriggerSourceTypeType for configuring the trigger source for an ADC Channel group.enum Adc_GroupConvModeTypeType for configuring the conversion mode of an ADC Channel group.Adc_GroupPriorityTypePriority level of the channel.Adc_GroupDefTypeType for assignment of channels to a channel group (this is not an API type).Adc_StreamNumSampleTypeType for configuring the number of group conversions in streaming access mode (in single access mode, parameter is 1).enum Adc_StreamBufferModeTypeType for configuring the streaming access mode buffer type.enum Adc_GroupAccessModeTypeType for configuring the access mode to group conversion results.Adc_HwTriggerSignalTypeType for configuring on which edge of the hardware trigger signal the driver should react, i.Adc_HwTriggerTimerTypeType for the reload value of the ADC module embedded timer (only if supported by the ADC hardware).Adc_PriorityImplementationTypeType for configuring the prioritization mechanism.Adc_GroupReplacementTypeReplacement mechanism, which is used on ADC group level, if a group conversion is interrupted by a group which has a higher...Adc_ChannelIn case of active limit checking: defines which conversion values are taken into account related to the boardes defineed with...Adc_ResultAlignmentTypeType for alignment of ADC raw results in ADC result buffer (left/ right alignment).enum Adc_PowerStateTypePower state currently active or set as target power state.enum Adc_PowerStateRequestResultTypeType Adc_PowerStateRequestResultType.
Funktionen & Typen — Detailansicht
fonction Adc_Init [SWS_Adc_00365] 📄 PDF
void Adc_Init (const Adc_ConfigType* ConfigPtr);
Initializes the ADC hardware units and driver.
La fonction synchrone Adc_Init (ID de service 0x00) sert à la configuration initiale et à la mise en service de toutes les unités matérielles ADC ainsi que du pilote ADC conformément à [SWS_Adc_00365]. L'interface est mise à disposition via le fichier d'en-tête Adc.h et ne possède aucune valeur de retour.
Paramètres et variantes de configuration
La transmission des données de configuration s'effectue via le paramètre pointeur ConfigPtr de type const Adc_ConfigType* [SWS_Adc_00365]. L'argument requis dépend de la variante de build choisie :
- En cas d'utilisation de la configuration post-build (
Variant PB),ConfigPtrdoit pointer vers la structure de données correspondante avec les valeurs d'initialisation. - Si la variante de précompilation (
Variant PC) est utilisée, l'interface exige explicitement la transmission d'unNULL_PTR[SWS_Adc_00365].
Concurrence et intégration système
La fonction Adc_Init est spécifiée comme non réentrante (Non Reentrant) [SWS_Adc_00365]. Interprétation : Étant donné que les unités matérielles sont configurées de manière globale et qu'il n'y a pas de réentrance, l'appel devrait typiquement avoir lieu de manière centralisée lors de l'initialisation du système, avant que d'autres fonctions du module ou conversions ne soient initiées. Question Q-a82e9204ae7a5ab7 (ouverte)
Concernant la gestion de l'énergie, il existe un couplage direct avec des exigences connexes : si l'état d'énergie normal (normal Power State) est demandé en fonctionnement, l'API correspondante doit recourir à des paramètres de configuration situés dans les mêmes conteneurs que les paramètres d'initialisation de Adc_Init [SWS_Adc_00483].
Cette note d'utilisation a été générée automatiquement sur la base de la spécification AUTOSAR R20-11.
Guide de l'implémenteur à venir (complexité I2)
fonction Adc_SetupResultBuffer [SWS_Adc_91000] 📄 PDF
Std_ReturnType Adc_SetupResultBuffer (Adc_GroupType Group, Adc_ValueGroupType* DataBufferPtr);
Initializes ADC driver with the group specific result buffer start address where the conversion results will be stored. The applicatio n has to ensure that the application buffer, where Data Buffer Ptr points to, can hold all the conversion results of the specified group. The initialization with Adc_ Setup Result Buffer is required after reset, before a group conversion can be started.
La fonction Adc_SetupResultBuffer initialise le pilote ADC avec l'adresse de début d'un tampon spécifique au groupe pour le stockage des résultats de conversion [SWS_Adc_91000]. Cet appel est impérativement requis après un reset avant de pouvoir démarrer une conversion de groupe [SWS_Adc_91000].
Paramètres et contexte d'appel
Group: identifiant numérique du groupe de canaux ADC demandé [SWS_Adc_91000].DataBufferPtr: pointeur vers le tampon de données (typeAdc_ValueGroupType*) dans lequel les résultats sont stockés [SWS_Adc_91000].
La fonction est déclarée réentrante et asynchrone, et est disponible via le fichier d'en-tête Adc.h (ID de service 0x0c) [SWS_Adc_91000].
Valeurs de retour et gestion des erreurs
Le type de retour est Std_ReturnType [SWS_Adc_91000] :
E_OK: le pointeur vers le tampon de résultats a été initialisé avec succès [SWS_Adc_91000].E_NOT_OK: l'opération a échoué ou une erreur de développement est survenue [SWS_Adc_91000].
Obligations de l'application
L'application appelante doit garantir que le tampon vers lequel pointe DataBufferPtr met à disposition un espace mémoire suffisant pour l'ensemble des résultats de conversion du groupe de canaux spécifié [SWS_Adc_91000].
Cette note d'utilisation a été générée automatiquement sur la base de la spécification d'AUTOSAR R20-11.
Guide de l'implémenteur à venir (complexité I2)
fonction Adc_DeInit [SWS_Adc_00366] 📄 PDF
void Adc_DeInit (void);
Returns all ADC HW Units to a state comparable to their power on reset state.
La fonction Adc_DeInit sert à la désinitialisation du pilote ADC et fait passer toutes les unités matérielles ADC associées dans un état comparable à l'état qui suit immédiatement un power-on reset [SWS_Adc_00366]. Elle rétablit ainsi l'état initial du matériel avant une nouvelle initialisation.
Appel et interface
La fonction est déclarée dans le fichier d'en-tête Adc.h et possède l'ID de service 0x01 [SWS_Adc_00366]. L'appel s'effectue de manière synchrone (Synchronous) et ne requiert aucun paramètre (ni In, InOut ni Out) ; aucune valeur de retour n'est non plus fournie (signature void Adc_DeInit(void)) [SWS_Adc_00366]. Aucun paramètre d'entrée ni valeur de retour n'est alors évalué ou généré. En raison de la sémantique synchrone, l'exécution bloque l'appelant jusqu'à ce que la réinitialisation de toutes les unités soit terminée [SWS_Adc_00366].
Concurrence et restrictions
Concernant la concurrence, la fonction est spécifiée comme non réentrante (Non Reentrant) [SWS_Adc_00366]. Il en découle l'interprétation : Des appels simultanés ou chevauchants de Adc_DeInit depuis plusieurs tâches ou différentes couches logicielles ne sont pas autorisés et doivent être coordonnés et évités par l'appelant.
Puisque Adc_DeInit rétablit complètement toutes les unités matérielles ADC dans l'état de reset [SWS_Adc_00366], il conviendrait de s'assurer avant l'appel qu'aucun processus de mesure ou de conversion n'est encore actif, afin d'empêcher un comportement indéfini du matériel. Question Q-15bfa2b822826786 (ouverte)
Ce texte a été généré par une IA et sert d'aide documentaire d'orientation.
Guide de l'implémenteur à venir (complexité I2)
fonction Adc_StartGroupConversion [SWS_Adc_00367] 📄 PDF
void Adc_StartGroupConversion (Adc_GroupType Group);
Starts the conversion of all channels of the requested ADC Channel group.
Utilisation
La fonction Adc_StartGroupConversion démarre la conversion de tous les canaux du groupe de canaux ADC transmis conformément à [SWS_Adc_00367]. L'ID de groupe numérique Group de type Adc_GroupType est transmis en paramètre. La fonction n'a pas de valeur de retour (void) et fonctionne de manière asynchrone ([SWS_Adc_00367]).
Concurrence et restrictions
Selon la spécification, le service est classé réentrant ([SWS_Adc_00367]). Interprétation : Cela devrait signifier que la fonction peut être appelée de manière concurrente pour différents groupes de canaux. Question Q-8283232f222f7b0a (ouverte) Comme le démarrage s'effectue de manière asynchrone, l'appel revient avant la fin de la conversion proprement dite.
Traitement des erreurs et interaction
Le service est disponible via l'en-tête Adc.h et possède l'ID de service 0x02 ([SWS_Adc_00367]). Les codes d'erreur DET ou DEM spécifiques ne sont pas documentés dans le présent payload.
Cette note d'utilisation est basée sur la spécification AUTOSAR R20-11 et a été générée automatiquement.
Guide de l'implémenteur à venir (complexité I2)
fonction Adc_StopGroupConversion [SWS_Adc_00368] 📄 PDF
void Adc_StopGroupConversion (Adc_GroupType Group);
Stops the conversion of the requested ADC Channel group.
La fonction synchrone Adc_StopGroupConversion met fin à la conversion en cours d'un groupe de canaux ADC demandé [SWS_Adc_00368]. L'interface est déclarée dans l'en-tête Adc.h et spécifiée sous l'ID de service 0x03 [SWS_Adc_00368].
La valeur d'entrée Group de type Adc_GroupType, qui représente l'ID numérique du groupe de canaux ADC respectif, est transmise comme unique paramètre [SWS_Adc_00368]. L'appel ne possède pas de valeur de retour (void) et n'utilise aucun paramètre d'entrée/sortie ni de sortie pure [SWS_Adc_00368].
Concernant le comportement en concurrence, le service est classé comme réentrant et présente une sémantique d'exécution synchrone [SWS_Adc_00368]. Des appels parallèles de l'interface sont par conséquent autorisés. Le comportement synchrone implique que l'opération est immédiatement terminée avec l'appel de fonction [SWS_Adc_00368].
Interprétation : Un appel devrait fonctionnellement présupposer qu'une conversion a été préalablement initiée pour le groupe concerné afin de pouvoir procéder à l'arrêt. Question Q-644ca5344ab849b0 (ouverte) Les codes d'erreur spécifiques, les valeurs de retour pour le signalement d'erreurs ou les messages destinés aux terminaux de développement (DET/DEM) ne sont pas indiqués pour ce service dans le présent extrait de spécification [SWS_Adc_00368].
Cette note d'utilisation a été générée de manière automatisée sur la base de la spécification AUTOSAR CP R20-11.
Guide de l'implémenteur à venir (complexité I1)
fonction Adc_ReadGroup [SWS_Adc_00369] 📄 PDF
Std_ReturnType Adc_ReadGroup (Adc_GroupType Group, Adc_ValueGroupType* DataBufferPtr);
Reads the group conversion result of the last completed conversion round of the requested group and stores the channe l values starting at the Data Buffer Ptr address. The group channel values are stored in ascending channel number order ( in contrast to the storage layout of the result buffer if streaming access is configured).
La fonction synchrone Adc_ReadGroup sert à la lecture des résultats de conversion d'un groupe de canaux ADC issus du cycle de conversion dernièrement achevé ([SWS_Adc_00369]). Elle est disponible via le fichier d'en-tête Adc.h et possède l'ID de service 0x04 ([SWS_Adc_00369]).
Paramètres et disposition du tampon
Group: Identifiant numérique du groupe de canaux ADC demandé ([SWS_Adc_00369]).DataBufferPtr: Pointeur vers le tampon de destination (Adc_ValueGroupType*), à partir de l'adresse duquel les résultats de conversion de tous les canaux du groupe sont déposés ([SWS_Adc_00369]).
Le stockage des valeurs de canaux s'effectue à partir de l'adresse de destination dans l'ordre croissant des canaux ([SWS_Adc_00369]). Cette disposition en mémoire diffère explicitement de l'agencement du tampon lors d'un accès en streaming configuré ([SWS_Adc_00369]). Interprétation : L'appelant devrait être responsable de fournir un tampon suffisamment dimensionné pour tous les canaux du groupe. Question Q-f22a12a6c7ab0eb3 (ouverte)
Valeurs de retour et gestion des erreurs
La valeur de retour de type Std_ReturnType signale l'état de l'opération de lecture ([SWS_Adc_00369]) :
E_OK: Des résultats sont disponibles et ont été écrits avec succès dans le tampon de données ([SWS_Adc_00369]).E_NOT_OK: Aucun résultat n'est disponible ou une erreur de développement est survenue ([SWS_Adc_00369]).
concurrence
La fonction est spécifiée comme réentrante ([SWS_Adc_00369]). Elle peut ainsi être exécutée en parallèle tant que des zones de tampon distinctes sont utilisées pour les accès simultanés.
Ce texte a été généré automatiquement à partir de la spécification AUTOSAR CP R20-11.
Guide de l'implémenteur à venir (complexité I2)
fonction Adc_EnableHardwareTrigger [SWS_Adc_91001] 📄 PDF
void Adc_EnableHardwareTrigger (Adc_GroupType Group);
Enables the hardware trigger for the requested ADC Channel group.
Utilisation et paramètres
La fonction Adc_EnableHardwareTrigger active le déclencheur matériel pour un groupe de canaux ADC configuré [SWS_Adc_91001]. Elle est définie comme un service avec l'ID de service 0x05 dans le module Adc et est disponible via le fichier d'en-tête Adc.h [SWS_Adc_91001].
- Paramètre d'entrée : l'ID numérique du groupe de canaux ADC souhaité est transmis via le paramètre
Groupde typeAdc_GroupType[SWS_Adc_91001]. Aucun paramètre d'entrée/sortie ou de sortie supplémentaire n'existe [SWS_Adc_91001]. - Valeur de retour : l'interface ne renvoie aucune valeur de retour (
void) [SWS_Adc_91001]. - Sémantique asynchrone : le comportement d'exécution est défini comme asynchrone [SWS_Adc_91001]. L'appel autorise le déclenchement, tandis que la conversion effective des canaux n'est amorcée que par des événements matériels ultérieurs.
concurrence
Le pilote spécifie Adc_EnableHardwareTrigger comme réentrante [SWS_Adc_91001]. Interprétation : la réentrance devrait principalement s'appliquer à l'appel simultané avec des groupes de canaux disjoints, étant donné que le déclencheur matériel est activé par groupe de canaux. Question Q-5750576df9f0284d (ouverte)
Cette note d'utilisation est basée sur la spécification AUTOSAR Classic R20-11.
Guide de l'implémenteur à venir (complexité I1)
fonction Adc_DisableHardwareTrigger [SWS_Adc_91002] 📄 PDF
void Adc_DisableHardwareTrigger (Adc_GroupType Group);
Disables the hardware trigger for the requested ADC Channel group.
La fonction Adc_DisableHardwareTrigger sert à désactiver le déclenchement matériel pour un groupe de canaux ADC demandé [SWS_Adc_91002].
Utilisation et sémantique
- Paramètres : Le paramètre
Groupde typeAdc_GroupTypeest transmis, spécifiant l'ID numérique du groupe de canaux ADC souhaité [SWS_Adc_91002]. - Valeur de retour : La fonction ne possède pas de valeur de retour (
void) [SWS_Adc_91002]. - Comportement d'exécution : L'appel est classé comme asynchrone (Sync/Async: Asynchronous) [SWS_Adc_91002]. Cela signifie probablement que l'arrêt effectif ou le découplage de l'événement matériel peut prendre effet de manière différée au niveau du matériel. Question Q-b0e613163b254242 (ouverte)
Concurrence et intégration
L'interface est déclarée comme réentrante (Reentrancy: Reentrant) et est mise à disposition via le fichier d'en-tête Adc.h ; son ID de service est 0x06 [SWS_Adc_91002]. Les codes d'erreur spécifiques, les contextes d'appel ou les notifications DET/DEM ne sont pas inclus dans le présent extrait de spécification.
Ce texte a été généré automatiquement. Toutes les informations reposent exclusivement sur la spécification d'AUTOSAR Classic R20-11.
Guide de l'implémenteur à venir (complexité I1)
fonction Adc_EnableGroupNotification [SWS_Adc_91003] 📄 PDF
void Adc_EnableGroupNotification (Adc_GroupType Group);
Enables the notification mechanism for the requested ADC Channel group.
La fonction Adc_EnableGroupNotification sert à activer le mécanisme de notification pour un groupe de canaux ADC demandé [SWS_Adc_91003]. La déclaration de cette interface est mise à la disposition des utilisateurs via le fichier d'en-tête Adc.h [SWS_Adc_91003].
Seul paramètre d'entrée, Group de type de données Adc_GroupType est transmis, définissant l'ID numérique du groupe de canaux ADC demandé [SWS_Adc_91003]. La fonction ne comporte aucun paramètre d'entrée/sortie ni de sortie, et ne renvoie aucune valeur de retour (void) [SWS_Adc_91003]. Le service est référencé sous l'ID de service 0x07 et présente une sémantique d'exécution asynchrone [SWS_Adc_91003].
En matière de comportement de concurrence, Adc_EnableGroupNotification est spécifiée comme réentrante [SWS_Adc_91003]. Plusieurs appels parallèles sont donc autorisés. La classification asynchrone de l'exécution devrait signifier que l'activation de la notification de groupe est mise en attente dans le pilote ou mise en œuvre en arrière-plan, sans bloquer le contexte appelant pendant le déroulement [SWS_Adc_91003]. Question Q-bae8fba7810fa269 (ouverte)
Le présent extrait de spécification n'établit aucune disposition supplémentaire concernant des erreurs spécifiques de développement ou de production (DET ou DEM), ni des conditions d'appel ou contextes de tâches exacts.
Cette note d'utilisation repose exclusivement sur les exigences de spécification de la version AUTOSAR R20-11.
Guide de l'implémenteur à venir (complexité I1)
fonction Adc_DisableGroupNotification [SWS_Adc_91004] 📄 PDF
void Adc_DisableGroupNotification (Adc_GroupType Group);
Disables the notification mechanism for the requested ADC Channel group.
La fonction Adc_DisableGroupNotification, déclarée dans l'en-tête Adc.h, sert dans le pilote ADC à désactiver de manière ciblée le mécanisme de notification pour un groupe de canaux ADC demandé [SWS_Adc_91004]. Le service possède l'ID de service 0x08 et est spécifié avec la signature void Adc_DisableGroupNotification (Adc_GroupType Group) [SWS_Adc_91004].
Paramètres et interface
Pour l'exécution de la fonction, la transmission d'un seul paramètre d'entrée est définie :
Group: transmet, sous la forme d'un identifiant numérique de typeAdc_GroupType, l'ID unique du groupe de canaux ADC souhaité dont la notification doit être désactivée [SWS_Adc_91004].
La fonction ne renvoie aucune valeur de retour (void) à l'appelant [SWS_Adc_91004]. De plus, selon la spécification, aucun paramètre combiné d'entrée/sortie (inout) ni aucun paramètre de sortie pur (out) n'est utilisé [SWS_Adc_91004].
Comportement d'exécution et concurrence
Concernant le comportement en matière de concurrence, Adc_DisableGroupNotification est classé comme réentrant [SWS_Adc_91004]. Cela autorise en principe l'appel parallèle ou avec interruption du service par différents contextes de programme [SWS_Adc_91004].
En ce qui concerne la synchronisation temporelle, la fonction est classée comme asynchrone [SWS_Adc_91004]. Interprétation : le comportement temporel étant explicitement déclaré comme asynchrone, la désactivation du mécanisme de notification devrait s'effectuer en arrière-plan en interne du pilote ou dans le matériel ADC, sans bloquer le contexte appelant jusqu'à son achèvement complet. Question Q-a1a30a254aa96655 (ouverte)
Cette note d'utilisation a été générée automatiquement et sert de guide d'orientation complémentaire à la spécification.
Rôle et intégration
La fonction Adc_DisableGroupNotification permet d'interrompre le mécanisme de notification associé à un groupe spécifique de canaux de conversion analogique-numérique [SWS_Adc_91004]. Publiée dans le fichier d'en-tête Adc.h, cette interface du pilote ADC porte l'identifiant de service 0x08 [SWS_Adc_91004].
Paramètres et sémantique d'appel
La signature formelle du service est void Adc_DisableGroupNotification (Adc_GroupType Group) [SWS_Adc_91004]. Son invocation met en jeu les paramètres suivants :
Group(en entrée) : identifiant numérique du groupe de canaux ADC pour lequel le mécanisme de notification doit être désactivé [SWS_Adc_91004].- Paramètres d'entrée/sortie (
inout) et de sortie (out) : aucun paramètre de ce type n'est utilisé par cette interface [SWS_Adc_91004]. - Valeur de retour : la fonction ne renvoie aucune valeur de statut ou de données (type de retour
void) [SWS_Adc_91004].
Propriétés d'exécution et concurrence
D'après les exigences de la spécification, cette fonction présente un fonctionnement asynchrone (Asynchronous) et garantit sa réentrance (Reentrant) [SWS_Adc_91004]. Elle peut donc être appelée de manière concurrente pour administrer différents groupes de canaux au sein du système sans créer de conflit d'exécution.
Cette note d'utilisation a été générée automatiquement à partir des exigences de la spécification AUTOSAR.
Guide de l'implémenteur à venir (complexité I1)
fonction Adc_GetGroupStatus [SWS_Adc_00374] 📄 PDF
Adc_StatusType Adc_GetGroupStatus (Adc_GroupType Group);
Returns the conversion status of the requested ADC Channel group.
fonction Adc_GetStreamLastPointer [SWS_Adc_00375] 📄 PDF
Adc_StreamNumSampleType Adc_GetStreamLastPointer (Adc_GroupType Group, Adc_ValueGroupType* * PtrToSamplePtr);
Returns the number of valid samples per channel, stored in the result buffer. Reads a pointer, pointing to a position in the group result buffer. With the pointer position, the results of all group channels of the last completed conversion round can be acc essed. With the pointer and the return value, all valid group conversion results can be accessed (the user has to take the layout of the result buffer into account).
fonction Adc_GetVersionInfo [SWS_Adc_00376] 📄 PDF
void Adc_GetVersionInfo (Std_VersionInfoType* versioninfo);
Returns the version information of this module.
fonction Adc_SetPowerState [SWS_Adc_00475] 📄 PDF
Std_ReturnType Adc_SetPowerState (Adc_PowerStateRequestResultType* Result);
This API configures the Adc module so that it enters the already prepared power state, chosen between a predefined set of configured ones.
La fonction de service synchrone Adc_SetPowerState fait passer le module ADC dans un état d'énergie préalablement préparé, sélectionné parmi un ensemble préconfiguré [SWS_Adc_00475].
Utilisation
La fonction est disponible via l'en-tête Adc.h et possède l'ID de service 0x10 [SWS_Adc_00475]. Elle ne prend aucun paramètre d'entrée, mais transmet le résultat via le paramètre de sortie Result de type Adc_PowerStateRequestResultType* [SWS_Adc_00475]. En cas d'activation réussie de l'état d'énergie, la fonction renvoie E_OK et signale via Result l'état ADC_SERVICE_ACCEPTED [SWS_Adc_00475].
Gestion des erreurs
Si la demande est rejetée, l'appel fournit la valeur de retour E_NOT_OK [SWS_Adc_00475]. Le module différencie alors dans le paramètre Result trois causes d'erreur spécifiques :
ADC_NOT_INIT: le module ADC n'est pas encore initialisé au moment de l'appel [SWS_Adc_00475].ADC_SEQUENCE_ERROR: l'ordre des appels d'API est incorrect [SWS_Adc_00475].ADC_HW_FAILURE: une erreur matérielle survenue empêche le passage à l'état demandé [SWS_Adc_00475].
Concurrence et restrictions
Adc_SetPowerState est non réentrante (Non Reentrant) et bloque l'appelant jusqu'à l'adoption synchrone de l'état [SWS_Adc_00475]. Selon l'interprétation retenue, une étape préalable de préparation à l'état cible doit obligatoirement avoir été exécutée avant l'appel, dans la mesure où la fonction requiert explicitement un état déjà préparé et rejette les erreurs d'ordonnancement par ADC_SEQUENCE_ERROR [SWS_Adc_00475].
Ce texte a été généré par une IA sur la base de la spécification AUTOSAR R20-11.
Guide de l'implémenteur à venir (complexité I2)
fonction Adc_GetCurrentPowerState [SWS_Adc_00476] 📄 PDF
Std_ReturnType Adc_GetCurrentPowerState (Adc_PowerStateType* CurrentPowerState, Adc_PowerStateRequestResultType* Result);
Service Adc_GetCurrentPowerState.
fonction Adc_GetTargetPowerState [SWS_Adc_00477] 📄 PDF
Std_ReturnType Adc_GetTargetPowerState (Adc_PowerStateType* TargetPowerState, Adc_PowerStateRequestResultType* Result);
Service Adc_GetTargetPowerState.
fonction Adc_PreparePowerState [SWS_Adc_00478] 📄 PDF
Std_ReturnType Adc_PreparePowerState (Adc_PowerStateType PowerState, Adc_PowerStateRequestResultType* Result);
This API starts the needed process to allow the ADC HW module to enter the AUTOSAR CP R20 - of Document ID : AUTOSAR_SWS_ADCDriver requested power state.
Utilisation et contexte d'appel
La fonction synchrone Adc_PreparePowerState déclenche le processus de préparation nécessaire pour faire passer le module matériel ADC dans un état de puissance demandé [SWS_Adc_00478]. Sont transmis comme paramètres l'état cible souhaité PowerState ainsi qu'un pointeur Result via lequel l'état de la requête est renvoyé [SWS_Adc_00478]. La valeur de retour signale par E_OK que le processus de préparation a été démarré, ou par E_NOT_OK que le service a été rejeté [SWS_Adc_00478].
Traitement des résultats et des erreurs
En cas de succès (E_OK), le paramètre de sortie Result fournit la valeur d'état ADC_SERVICE_ACCEPTED [SWS_Adc_00478]. Si le service a été rejeté avec E_NOT_OK, Result précise la cause exacte [SWS_Adc_00478] :
ADC_NOT_INIT: le module ADC n'est pas encore initialisé [SWS_Adc_00478].ADC_SEQUENCE_ERROR: séquence d'appel non valide, car l'état actuel correspond déjà à l'état cible [SWS_Adc_00478].ADC_POWER_STATE_NOT_SUPP: l'état de puissance demandé n'est pas pris en charge par le module [SWS_Adc_00478].ADC_TRANS_NOT_POSSIBLE: une transition directe n'est pas possible ou le périphérique matériel est encore occupé [SWS_Adc_00478].
Concurrence et interaction
La fonction est spécifiée comme non réentrante [SWS_Adc_00478]. Par conséquent, l'appelant doit s'assurer que les appels s'effectuent séquentiellement et sans chevauchement. Les appelants devraient devoir achever ou interrompre au préalable les conversions en cours, car un périphérique matériel actif entraîne un rejet. Question Q-210c59a46a90d781 (ouverte) Après une préparation réussie par Adc_PreparePowerState, les actions consécutives sans effet immédiat visant à finaliser la transition d'état sont exécutées via une API subséquente associée [SWS_Adc_00499].
Cette note d'utilisation a été générée automatiquement et repose exclusivement sur les données de spécification issues de SWS_Adc_00478 et SWS_Adc_00499.
Guide de l'implémenteur à venir (complexité I2)
fonction Adc_Main_PowerTransitionManager [SWS_Adc_00479] 📄 PDF
void Adc_Main_PowerTransitionManager (void);
This API is cyclically called and supervises the power state transitions, checking for the readiness of the module and issuing the callbacks Io Hw Ab_ Adc_ Notify Ready For Power State
Utilisation et contexte d'appel
La fonction principale Adc_Main_PowerTransitionManager sert à la surveillance cyclique et au déroulement des transitions d'état d'alimentation dans le module ADC [SWS_Adc_00479]. Elle possède la signature void Adc_Main_PowerTransitionManager(void), ne prend aucun paramètre d'entrée et ne renvoie aucune valeur [SWS_Adc_00479]. La fonction est appelée cycliquement et déclarée via l'en-tête SchM_Adc.h [SWS_Adc_00479]. L'appel devrait donc typiquement s'effectuer dans le contexte de tâche cyclique du planificateur BSW (SchM). Question Q-4fc01e5bed5b3b57 (ouverte)
Surveillance d'état et séquences asynchrones
Pendant l'exécution cyclique, la fonction vérifie en continu la disponibilité opérationnelle du module pour l'état d'alimentation demandé [SWS_Adc_00479]. Dès que la disponibilité du module est constatée, elle émet les rappels de notification IoHwAb_Adc_NotifyReadyForPowerState<Mode> référencés via le paramètre de configuration AdcPowerStateReadyCbkRef [SWS_Adc_00479]. Toutes les opérations asynchrones nécessaires à l'atteinte de l'état d'alimentation cible peuvent être traitées en arrière-plan dans le contexte d'exécution de Adc_Main_PowerTransitionManager [SWS_Adc_00498].
Gestion des erreurs et conditions limites
Si un état d'alimentation demandé ne peut pas être atteint directement à partir de l'état d'alimentation actuel, l'API signale l'erreur d'exécution ADC_E_TRANSITION_NOT_POSSIBLE [SWS_Adc_00498]. L'externalisation des processus de transition plus longs dans cette fonction gestionnaire cyclique évite de bloquer les appelants de niveau supérieur pendant que le module ADC finalise le changement d'état en arrière-plan [SWS_Adc_00498].
Cette note d'utilisation a été générée de manière automatisée sur la base de la spécification AUTOSAR Classic R20-11.
Guide de l'implémenteur à venir (complexité I1)
fonction IoHwAb_Adc_NotifyReadyForPower [SWS_Adc_00480] 📄 PDF
void IoHwAb_Adc_NotifyReadyForPowerState<#Mode> (void);
The API shall be invoked by the ADC Driver when the requested power state preparation for mode <#Mode> is completed.
La fonction IoHwAb_Adc_NotifyReadyForPower sert d'interface de notification de l'abstraction matérielle d'E/S et est appelée par le pilote ADC dès que la préparation pour un état de puissance demandé dans le mode <#Mode> est terminée [SWS_Adc_00480]. La déclaration de cette interface est fournie par le fichier d'en-tête IoHwAb_Adc.h [SWS_Adc_00480].
Contexte d'appel et sémantique
Conformément à la spécification, les conditions-cadres suivantes s'appliquent à l'appel [SWS_Adc_00480] :
- Paramètres et valeur de retour : la fonction ne possède aucun paramètre d'entrée, de sortie ni d'entrée/sortie et ne renvoie aucune valeur de retour (
void) [SWS_Adc_00480]. - Synchronicité : le comportement d'exécution est défini comme synchrone [SWS_Adc_00480].
- Réentrance : la fonction est classée comme non réentrante (
Non Reentrant) [SWS_Adc_00480]. Les appelants doivent par conséquent s'assurer que les appels sont séquentiels et ne se chevauchent pas de manière concurrente.
Interaction et gestion des erreurs
Aucun code d'erreur ni notification destinée à DET ou DEM ne figure dans les données de spécification [SWS_Adc_00480]. L'indication de syntaxe IoHwAb_Adc_NotifyReadyForPowerState<#Mode> suggère que l'identifiant est généré spécifiquement en fonction du mode de puissance configuré. Question Q-9e9c969f8a41d0de (ouverte) La fonction agit probablement en tant que callback du pilote afin d'indiquer à la gestion de puissance de niveau supérieur l'état de préparation pour le changement.
Ce texte a été généré par une IA sur la base de la spécification SWS_Adc_00480.
Guide de l'implémenteur à venir (complexité I1)
type Adc_ConfigType [SWS_Adc_00505] 📄 PDF
Data structure containing the set of configuration parameters required for initializing the ADC Driver and ADC HW Unit(s).
type Adc_ChannelType [SWS_Adc_00506] 📄 PDF
Numeric ID of an ADC channel.
type Adc_GroupType [SWS_Adc_00507] 📄 PDF
Numeric ID of an ADC channel group.
type Adc_ValueGroupType [SWS_Adc_00508] 📄 PDF
Type for reading the converted values of a channel group (raw, without further scaling, alignment according precompile switch ADC_ RESULT_ ALIGNMENT).
type Adc_PrescaleType [SWS_Adc_00509] 📄 PDF
Type of clock prescaler factor. (This is not an API type).
type Adc_ConversionTimeType [SWS_Adc_00510] 📄 PDF
Type of conversion time, i.e. the time during which the sampled analogue value is converted into digital representation. (This is not an API type).
type Adc_SamplingTimeType [SWS_Adc_00511] 📄 PDF
Type of sampling time, i.e. the time during which the value is sampled, (in clock - cycles). (This is not an API type).
type Adc_ResolutionType [SWS_Adc_00512] 📄 PDF
Type of channel resolution in number of bits. (This is not an API type).
type Adc_StatusType [SWS_Adc_00513] 📄 PDF
Current status of the conversion of the requested ADC Channel group.
Le type énuméré Adc_StatusType représente, selon [SWS_Adc_00513], l'état de conversion actuel d'un groupe de canaux ADC demandé et est mis à disposition via l'en-tête Adc.h.
Les valeurs d'énumération reflètent la progression de la conversion analogique-numérique ainsi que la disponibilité des résultats [SWS_Adc_00513] :
ADC_IDLE(0x00) : la conversion du groupe indiqué n'a pas encore été démarrée ; aucun résultat de mesure n'est disponible [SWS_Adc_00513].ADC_BUSY(0x01) : la conversion du groupe a démarré et est actuellement en cours ; aucun résultat n'est disponible jusqu'à présent [SWS_Adc_00513].ADC_COMPLETED(0x02) : un cycle de conversion (qui n'est pas le cycle final) du groupe est achevé ; un résultat est disponible pour tous les canaux du groupe [SWS_Adc_00513].ADC_STREAM_COMPLETED(0x03) : le tampon de résultats est entièrement rempli ; le nombre requis d'échantillons est disponible pour chaque canal du groupe sélectionné [SWS_Adc_00513].
Dans les applications, ce type sert généralement à interroger ou évaluer la progression du groupe afin de déterminer si des résultats peuvent déjà être lus ou si d'autres échantillonnages sont en attente.
Ce texte a été généré par une IA sur la base de la spécification AUTOSAR CP R20-11.
Guide de l'implémenteur à venir (complexité I1)
type Adc_TriggerSourceType [SWS_Adc_00514] 📄 PDF
Type for configuring the trigger source for an ADC Channel group.
type Adc_GroupConvModeType [SWS_Adc_00515] 📄 PDF
Type for configuring the conversion mode of an ADC Channel group. AUTOSAR CP R20 - of Document ID : AUTOSAR_SWS_ADCDriver
Le type énuméré Adc_GroupConvModeType sert à configurer le mode de conversion d'un groupe de canaux ADC et est déclaré par le biais du fichier d'en-tête Adc.h [SWS_Adc_00515]. Ce type définit si les canaux d'un groupe sont convertis une seule fois ou de façon répétée après l'événement de déclenchement configuré [SWS_Adc_00515].
Deux modes sont disponibles pour la configuration [SWS_Adc_00515] :
-
ADC_CONV_MODE_ONESHOT(0x00) : exécute exactement une conversion de chaque canal du groupe de canaux ADC après l'événement de déclenchement configuré [SWS_Adc_00515]. Si un déclencheur logiciel a été configuré comme source de déclenchement, une conversion démarrée peut être arrêtée via un appel d'API logicielle [SWS_Adc_00515]. En revanche, si une source de déclenchement matériel est assignée, une conversion ponctuelle (one-shot) démarrée peut être suspendue par la désactivation de l'événement de déclenchement, sous réserve de prise en charge par le matériel [SWS_Adc_00515]. -
ADC_CONV_MODE_CONTINUOUS(0x01) : effectue en continu des conversions répétées de chaque canal au sein du groupe de canaux [SWS_Adc_00515]. Ce mode continu est exclusivement disponible pour les groupes disposant d'une source de déclenchement logiciel [SWS_Adc_00515]. Un cycle de conversion continu déjà démarré peut être interrompu à tout moment au moyen d'un appel d'API logicielle [SWS_Adc_00515].
En ce qui concerne les restrictions, il convient de noter que ADC_CONV_MODE_CONTINUOUS n'est autorisé qu'avec un déclenchement logiciel et ne peut pas être combiné avec des sources de déclenchement matériel [SWS_Adc_00515]. Avec les déclencheurs logiciels, l'arrêt des conversions en cours requiert un appel d'API logicielle dédié, tandis que les séquences ponctuelles à déclenchement matériel exigent la désactivation de l'événement de déclenchement [SWS_Adc_00515].
Ce texte a été généré par une IA et repose exclusivement sur les données de spécification d'AUTOSAR R20-11.
Guide de l'implémenteur à venir (complexité I1)
type Adc_GroupPriorityType [SWS_Adc_00516] 📄 PDF
Priority level of the channel. Lowest priority is 0.
type Adc_GroupDefType [SWS_Adc_00517] 📄 PDF
Type for assignment of channels to a channel group (this is not an API type).
type Adc_StreamNumSampleType [SWS_Adc_00518] 📄 PDF
Type for configuring the number of group conversions in streaming access mode (in single access mode, parameter is 1). Available Adc.h AUTOSAR CP R20 - of Document ID : AUTOSAR_SWS_ADCDriver via
type Adc_StreamBufferModeType [SWS_Adc_00519] 📄 PDF
Type for configuring the streaming access mode buffer type.
Le type d'énumération Adc_StreamBufferModeType sert à configurer le comportement de tampon en mode d'accès streaming du pilote ADC et est disponible via le fichier d'en-tête Adc.h [SWS_Adc_00519].
Le type définit deux modes de fonctionnement spécifiques pour la gestion de tampon lors de conversions en streaming [SWS_Adc_00519] :
ADC_STREAM_BUFFER_LINEAR(valeur0x00) : le pilote ADC met automatiquement fin à la conversion dès que le tampon de flux est plein ou que le nombre défini d'échantillons est atteint [SWS_Adc_00519].ADC_STREAM_BUFFER_CIRCULAR(valeur0x01) : le pilote ADC poursuit la conversion même après avoir atteint la capacité totale du tampon, en revenant au début du tampon et en l'écrasant de manière circulaire [SWS_Adc_00519].
Les couches d'intégration et les logiciels d'application doivent adapter le comportement de tampon à la stratégie de traitement respective : alors que ADC_STREAM_BUFFER_LINEAR est prévu pour des séries de mesures autonomes avec une taille d'échantillon fixe, ADC_STREAM_BUFFER_CIRCULAR exige vraisemblablement une surveillance continue du tampon ou un prélèvement rapide des données afin d'éviter une perte de données inaperçue due à l'écrasement automatique [SWS_Adc_00519]. Question Q-23b411e5e6c50591 (ouverte)
Ce texte a été généré par une IA sur la base de la spécification AUTOSAR Classic R20-11.
Guide de l'implémenteur à venir (complexité I1)
type Adc_GroupAccessModeType [SWS_Adc_00528] 📄 PDF
Type for configuring the access mode to group conversion results.
Le type d'énumération Adc_GroupAccessModeType sert à configurer le mode d'accès aux résultats de conversion d'un groupe de canaux ADC conformément à [SWS_Adc_00528]. La définition du type est mise à disposition via le fichier d'en-tête Adc.h et détermine la manière dont les résultats sont stockés en mémoire.
Pour la configuration du mode d'accès du groupe, deux valeurs sont définies dans la spécification [SWS_Adc_00528] :
ADC_ACCESS_MODE_SINGLE(valeur0x00) : configure le mode d'accès à valeur unique (Single value access mode) pour le groupe concerné.ADC_ACCESS_MODE_STREAMING(valeur0x01) : configure le mode d'accès en streaming (Streaming access mode) pour le groupe concerné.
Ce type est utilisé lors de la configuration du pilote ADC pour contrôler le comportement d'accès aux tampons des résultats de conversion [SWS_Adc_00528]. Interprétation : alors que le mode valeur unique est vraisemblablement conçu pour fournir une seule valeur de résultat actuelle par canal de groupe, le mode streaming est probablement prévu pour des séries de mesures plus continues comportant plusieurs valeurs de tampon. Question Q-8a933cffcd1132ef (ouverte)
Puisqu'il s'agit d'un type de configuration pur, l'exigence ne définit pas de codes d'erreur propres, de valeurs de retour ou de messages DET/DEM pour ce type [SWS_Adc_00528].
Ce texte a été généré par une IA sur la base de la spécification AUTOSAR Classic R20-11.
Guide de l'implémenteur à venir (complexité I1)
type Adc_HwTriggerSignalType [SWS_Adc_00520] 📄 PDF
Type for configuring on which edge of the hardware trigger signal the driver should react, i.e. start the conversion (only if supported by the ADC hardware).
type Adc_HwTriggerTimerType [SWS_Adc_00521] 📄 PDF
Type for the reload value of the ADC module embedded timer (only if supported by the ADC hardware).
type Adc_PriorityImplementationType [SWS_Adc_00522] 📄 PDF
Type for configuring the prioritization mechanism.
type Adc_GroupReplacementType [SWS_Adc_00523] 📄 PDF
Replacement mechanism, which is used on ADC group level, if a group conversion is interrupted by a group which has a higher priority.
type Adc_Channel [SWS_Adc_00524] 📄 PDF
In case of active limit checking: defines which conversion values are taken into account related to the boardes defineed with Adc Channel Low Limit and Adc Channel High Limit.
type Adc_ResultAlignmentType [SWS_Adc_00525] 📄 PDF
Type for alignment of ADC raw results in ADC result buffer (left/ right alignment).
Utilisation et plage de valeurs
Le type énuméré Adc_ResultAlignmentType est fourni via le fichier d'en-tête Adc.h et sert, dans le module Adc, à définir l'alignement des valeurs brutes d'ADC dans le tampon de résultat [SWS_Adc_00525]. Il constitue l'interface standardisée pour configurer le stockage dans le tampon du pilote [SWS_Adc_00525]. En tant que type de données pur, il ne possède pas de paramètres de fonction propres, de valeurs de retour ou de sémantique asynchrone [SWS_Adc_00525].
La plage de valeurs de l'énumération comprend exactement deux valeurs selon la spécification [SWS_Adc_00525] :
-
ADC_ALIGN_LEFT(valeur numérique0x00) : configure un alignement à gauche des résultats de conversion dans le tampon [SWS_Adc_00525]. -
ADC_ALIGN_RIGHT(valeur numérique0x01) : configure un alignement à droite des résultats de conversion dans le tampon [SWS_Adc_00525].
Signification et conditions aux limites
La valeur choisie détermine les positions de bits de la zone de tampon où sont stockées les données brutes après une conversion [SWS_Adc_00525]. Cela permet de définir si les bits de données significatifs se situent alignés à gauche ou à droite en mémoire [SWS_Adc_00525]. Interprétation : la fixation d'un alignement à gauche ou à droite devrait être particulièrement pertinente lorsque la résolution matérielle du convertisseur analogique-numérique est inférieure à la largeur d'élément de la mémoire tampon allouée. Les composants logiciels en aval doivent tenir compte de l'alignement configuré afin de pouvoir lire les valeurs brutes sans erreurs de calcul ou de décalage de bits. Question Q-54221124172a3d87 (ouverte)
Il n'existe pas de codes d'erreur spécifiques, de messages DET ou DEM pour cette énumération [SWS_Adc_00525].
Cette note d'utilisation a été générée automatiquement et repose sur la spécification AUTOSAR R20-11.
type Adc_PowerStateType [SWS_Adc_00526] 📄 PDF
Power state currently active or set as target power state.
Le type énuméré Adc_PowerStateType définit dans AUTOSAR Classic l'état d'alimentation du pilote ADC [SWS_Adc_00526]. Il est utilisé dans le pilote pour représenter soit l'état de fonctionnement actuellement adopté par le module, soit pour spécifier un nouvel état cible à atteindre pour la gestion de l'énergie [SWS_Adc_00526]. La déclaration de ce type de données est mise à disposition via l'en-tête Adc.h [SWS_Adc_00526].
Pour les différents états de l'énumération, la spécification établit un ordre hiérarchique concernant la consommation de puissance [SWS_Adc_00526] :
ADC_FULL_POWER(valeur numérique 0) : désigne le mode de fonctionnement et de pleine fonctionnalité du pilote ADC sans restrictions de courant [SWS_Adc_00526].- Plage de valeurs de 1 à 255 : représente des modes d'économie d'énergie optionnels avec une réduction progressive de la consommation de puissance [SWS_Adc_00526].
En ce qui concerne l'interaction et l'intégration dans l'environnement système, l'interprétation suivante s'applique : le type devrait principalement servir de paramètre de transmission dans les fonctions de commande pour les transitions d'état d'alimentation (Power-State), ainsi que pour le retour d'état vers des modules de niveau supérieur tels que la gestion d'état du BSW ou de l'ECU. Question Q-e4f964bd79ad550c (ouverte) Puisqu'il s'agit d'une définition de type de données élémentaire, les propriétés spécifiques telles que les contextes d'appel, les exigences de réentrance, la sémantique synchrone ou asynchrone, ainsi que les erreurs d'exécution et les notifications DET ne sont définies que dans les API de pilote associées et ne font pas partie de cette description de type [SWS_Adc_00526].
Ce texte a été généré par une IA. Il repose exclusivement sur les spécifications de la version AUTOSAR R20-11.
Guide de l'implémenteur à venir (complexité I1)
type Adc_PowerStateRequestResultType [SWS_Adc_00527] 📄 PDF
Type Adc_PowerStateRequestResultType.
Le type énuméré Adc_PowerStateRequestResultType définit les valeurs de retour pour les demandes de transition d'état au sein de la gestion de puissance du pilote ADC et est mis à disposition via le fichier d'en-tête Adc.h [SWS_Adc_00527].
Les valeurs du type représentent le succès ou des causes d'erreur spécifiques d'un changement d'état de puissance demandé [SWS_Adc_00527] :
ADC_SERVICE_ACCEPTED(0) : le passage à l'état souhaité a été exécuté avec succès [SWS_Adc_00527].ADC_NOT_INIT(1) : l'appel a échoué car le module ADC n'est pas encore initialisé [SWS_Adc_00527].ADC_SEQUENCE_ERROR(2) : l'ordre des appels aux API est incorrect [SWS_Adc_00527].ADC_HW_FAILURE(3) : une erreur matérielle empêche le passage à l'état requis [SWS_Adc_00527].ADC_POWER_STATE_NOT_SUPP(4) : l'état de puissance requis n'est pas pris en charge par le module ADC [SWS_Adc_00527].ADC_TRANS_NOT_POSSIBLE(5) : une transition directe de l'état actuel vers l'état souhaité n'est pas possible ou le périphérique matériel est encore occupé [SWS_Adc_00527].
Les appelants doivent évaluer la valeur de retour pour faire la distinction entre une exécution régulière et des conditions d'erreur telles qu'une séquence incorrecte, une absence d'initialisation du module ou des conflits matériels [SWS_Adc_00527].
Ce texte a été généré par une IA sur la base de la spécification.
Guide de l'implémenteur à venir (complexité I1)
Request a governed re-review of this record. The record is not changed immediately.
- Record
AUTOSAR/AP/record/CP_MOD_Adc- Status
- unspecified
- Version
AUTOSAR/AP/record/CP_MOD_Adc@rel:R20-11#3954ff98- Content hash
3954ff98- Source
- https://www.autosar.org/fileadmin/standards/R20-11/CP/AUTOSAR_SWS_ADCDriver.pdf#nameddest=SWS_Adc_00365
gemini-3.8-flash-low· 2026-10-13 · Original allemand